MSMAware Computation

ADVANCED MODE

 

 

General data:

 

Location                      : Air Terjun Sungai Batu, Kuala Lumpur

Area                            : 10 Hectare

Time, Tc                      : 30 Minutes

²P24                             : 100 mm

Site Condition              : a) SemiD Houses

b) Park

c) Commercial

 

 

Step 1: Start MSMAware and click “Rational Method”. Make sure to compute the storm result before run the rational method. Follow steps shown in chapter 1 for design storm.

 

Step 2: Check only “MSMA2”.

 

Step 3: Click “Get IDF data from STORM” box to use the data in the DETENTION BASIN module.

 

Note

 

Step 4: Select site condition according to site project. Do for both “Pre” and “Post” tab.

 

Step 5: Select ‘Run’ button and the values for discharge (Q), runoff coefficient (C), rainfall intensity (I) and area (A) will be generated automatically.

 

Step 6: Click “Report” button to generate a report for rational method.

 

 

Back : Case Study 1 Kuala Lumpur                       Next : Manual Calculation

 

Print This Page Print This Page